5kWh vs 10kWh vs 15kWh Solar Battery: Which Size Is Right?
A 5kWh, 10kWh or 15kWh solar battery can each be the right choice; what matters is the electricity your home needs between charging opportunities. A smaller battery may cover modest evening use, while a larger one can carry more energy into the night and following morning. But extra capacity only helps when you can charge it and put that energy to good use. Your routine tells us more than the number of bedrooms.
At Sustainable Energy Engineering , we want you to understand what you are paying for. You should not feel that you have to choose the biggest battery to avoid making a mistake. If its last few kilowatt-hours rarely get charged or used, a smaller system may be the better investment. Equally, there is little sense in choosing too little storage for demand you genuinely have.
We will walk you through the three sizes, explain what the capacity figures mean and show how solar, overnight charging, electric heating and backup affect the decision. The examples are there to make the numbers easier to understand, not to suggest that your household should behave like an average home or achieve a guaranteed saving.
Choose the Capacity You Will Use
- Start with 5kWh if the demand you want to shift is modest and a larger battery would often retain unused energy.
- Compare 10kWh if measured evening, overnight and early-morning demand regularly exceeds what a 5kWh system can supply.
- Consider 15kWh if that larger demand is real, solar or permitted grid charging can replenish it, and the extra cost is justified.
- Check kW as well as kWh. Enough stored energy does not guarantee enough power for several appliances running together.
- Ask for all three options on the same assumptions. The useful comparison is the extra annual benefit of each step up in size.
5kWh vs 10kWh vs 15kWh: What Changes?
A kilowatt-hour measures a quantity of energy. Moving from 5 to 10kWh of usable capacity gives you twice the storage space, but it does not automatically double your saving, charging speed or output power. Those depend on the rest of the system and how you use it. We need to look at the whole arrangement, not just the size on the label.
5kWh: Cover a Modest Daily Gap
A 5kWh option is worth looking at if you use relatively little electricity once solar generation falls, or your panels have limited surplus. It may cover background demand and part of your evening, leaving the grid to supply bigger or longer-running loads. We would compare that with what your home actually uses.
What we would look for: whether cooking, heating or overnight demand would regularly empty it earlier than you need.
10kWh: Cover a Larger Daily Gap
A 10kWh option becomes more interesting when a smaller battery would regularly fill and then run out while you still need electricity. It can keep more daytime surplus for the evening and following morning, provided there is enough opportunity to charge it. That is a practical reason to step up in size.
What we would avoid: asking you to pay for extra capacity simply because 10kWh sounds like a standard household size.
15kWh: Support Substantial Demand
A 15kWh option may suit substantial demand outside solar-generating or cheap-rate periods, a defined backup requirement or realistic plans for more electrical equipment. We still need a credible charging plan and enough useful discharge to justify the extra cost. A larger battery needs a clear purpose in your home.
What we would check: whether much of that capacity would sit unused, or whether the inverter would limit the benefit.
These are comparison sizes, rather than three exact products we expect you to choose between. Manufacturers use different module sizes and capacity definitions, so your quotation might say 9.5, 10.24 or 13.5kWh. We compare the actual specification and settings with you instead of rounding every system into a category and overlooking the differences.
One Consistent Basis for Our Numerical Examples
To keep the examples fair, we treat 5, 10 and 15kWh as usable energy inside the battery on the DC side , after the manufacturer's protective buffer. We assume 95% charging efficiency and 95% discharge efficiency, giving 90.25% round-trip efficiency . There is no additional customer backup reserve in the main comparisons. These are shared assumptions for the examples, not specifications for a particular battery.
In this AC-coupled example, we measure charging electricity at the home's AC supply before storage, and delivered electricity at the AC supply back to your home. Your solar installation may use a different conversion path. For your proposal, we would use the efficiency figures that match that design rather than carry these assumptions across automatically.
| Comparison | 5kWh | 10kWh | 15kWh |
|---|---|---|---|
| Usable stored energy, before customer reserve | 5.00kWh | 10.00kWh | 15.00kWh |
| Energy delivered to the home from a full usable charge | 4.75kWh | 9.50kWh | 14.25kWh |
| Delivered energy if 20% of usable capacity is held back | 3.80kWh | 7.60kWh | 11.40kWh |
| AC charging energy to refill the full usable capacity | 5.26kWh | 10.53kWh | 15.79kWh |
| Average battery charging input needed over four hours | 1.32kW | 2.63kW | 3.95kW |
| Continuous output power | Check the battery and inverter specification. Capacity alone does not establish the kW rating. | ||
The rounded charging figures show a refill of the entire usable capacity, not a top-up when energy is already stored. They exclude separately measured standby or auxiliary use. Real charging may slow near full charge or be restricted by temperature, controls and the available electrical supply. We allow for those practical limits when looking at your charging window.
Nominal Capacity, Usable Capacity and Delivered Energy Are Different
There are three figures worth separating. Nominal capacity is the manufacturer's stated total energy capacity on its defined basis. Usable capacity is the part available within the permitted operating range. Energy delivered to your home is another question again: a usable figure may refer to DC energy inside the battery or AC energy from the complete system. We explain which one your quotation uses.
For example, the UK Powerwall 3 specification gives 13.5kWh of usable AC energy under its stated test conditions. That is not the same measurement as 13.5kWh of DC storage. Taking our example's discharge loss off that AC figure again would count the same conversion twice. A fair comparison starts by putting both batteries on a matching basis.
Do Not Deduct the Same Buffer or Loss Twice
The same care applies to protective limits and reserve settings. If usable capacity already excludes the manufacturer's protective minimum, we should not deduct another generic depth-of-discharge allowance. If the figure includes AC conversion, we should not subtract that loss again. Any extra reserve you choose for backup needs its own explanation on the manufacturer's charge scale.
Here is how our example works. A full 10kWh usable DC battery delivers 10 × 0.95 = 9.5kWh to the home. Filling it from its usable minimum takes 10 ÷ 0.95 = 10.53kWh at the AC charging input. The difference between what goes in and what comes back is the round-trip loss, not missing capacity that we should deduct for a second time.
You should not have to untangle these definitions yourself. Ask us to explain the nominal and usable capacities, the normal minimum charge, any extra reserve and the energy expected at your chosen settings. Those details tell you much more than a large kWh figure with an unexplained percentage beside it. Our usable versus nominal capacity guide takes you through those definitions step by step.
Start with When Your Home Uses Electricity
An annual bill gives us a starting point, but it does not tell us when you need stored electricity. A home using 3,650kWh a year averages 10kWh a day; that does not automatically make a 10kWh battery right. Some electricity may come directly from solar, some may be used during cheap periods, and your winter demand may be much higher than your summer demand.
We look for the demand left in the hours you want the battery to cover . With solar, that often means late afternoon, evening, overnight and the following morning. With tariff charging, it may mean the gap between two cheaper windows. Those are different jobs, so we need to know which one you want your battery to do.
The Information That Makes Sizing More Accurate
- Electricity bills: establish annual consumption and seasonal differences.
- Half-hourly meter data: show when electricity is imported and how demand changes through the day.
- Solar monitoring: show generation, direct use, export and existing battery behaviour where available.
- Household routine: include working from home, cooking, laundry and overnight background loads.
- Large electrical loads: identify an EV, heat pump, immersion heater, electric shower or other substantial demand.
- Planned changes: distinguish equipment you have committed to from possibilities you may never install.
Already have solar? Your smart-meter imports will not show all the electricity your household uses. Some appliances are supplied directly by the panels before an import is recorded, and an existing battery may cover more demand. Where available, we bring together import and export records, generation and storage measurements to build a fuller picture of your home.
You do not need perfect data before getting in touch. We can start with your bills and routine, while being clear about what remains uncertain. A short monitoring period may help us understand evening use, but it is not a full year's evidence. We would not treat a sunny summer week as a reliable picture of your winter storage needs.
The Question to Answer Before Choosing a Size
The question we work through with you is: "From the end of useful solar generation or cheap charging until the next charging opportunity, how much electricity will your home need, and how much is worth supplying from the battery?"
Match Battery Size to Surplus Solar, Not Panel Wattage Alone
Your solar panels first supply electricity being used at the same time. What remains is the surplus that could go into storage or be exported. This is why we look beyond total generation: a productive roof may still leave little for a battery if your home uses most of the electricity straight away.
Imagine your panels generate 20kWh during a day and your home uses 8kWh directly. That leaves 12kWh before storage, diversion or export. Through our assumed AC charging path, it can store 12 × 0.95 = 11.4kWh , later returning up to 10.83kWh . A 15kWh battery has room for that energy, but the surplus would not fill it completely from its usable minimum.
Now picture the same array on a home where someone is in all day, an EV charges from solar or a heat pump is running. There may be much less surplus to store. A home that is empty in daylight may export heavily and then buy electricity after dark. Neither routine is wrong; they simply create different storage opportunities.
Why There Is No Fixed Battery-to-Panel Ratio
It also helps to keep panel and battery ratings separate. Solar kWp is rated generating power under standard conditions; battery kWh is stored energy. Roof direction, shading, weather, inverter limits and your electricity use all affect the relationship. A rule such as "a 4kWp array needs a 10kWh battery" cannot answer the question for every home.
When you are considering new solar PV panels , we assess the array and storage together. Your roof determines how much electricity can be generated and when. Your routine tells us how much can be used immediately and how much remains worth keeping for later.
Summer and Winter Pull the Decision in Different Directions
Summer and winter can tell quite different stories. On a long bright day, the battery may fill early and leave further solar for export or another useful load. In winter, there may not be enough generation to fill even a small battery, just as heating use increases. Buying more storage space cannot make up for electricity that has not been generated.
A larger battery can carry energy into another day within its available capacity, but ordinary home storage cannot save summer surplus for winter. We need an annual comparison that follows the charge level through consecutive days, including cloudy spells and time away, rather than treating every morning as a fresh full battery.
Check Which Limit You Are Actually Reaching
A useful clue is whether a smaller battery fills while solar is still available, then empties before you have finished using electricity. More capacity may help in that situation. If it rarely fills, we would first look at surplus generation, charge power, settings and temperature. A bigger battery is not automatically the answer to every disappointing result.
Worked Examples: When Each Size Adds Something Useful
Let's compare four simple days. In each example, the battery starts at its usable minimum, the stated solar surplus is available before the later demand, and the example ends after that demand. We assume no grid charging, extra reserve or energy carried over from yesterday. Charging and discharge power are sufficient for the timings, so we can focus on capacity.
These deliberately simplified days help you see what changes when the battery gets bigger. They are not customer results or a full-year forecast. In your home, generation and demand overlap, charging may not finish, and energy can remain for tomorrow. A design assessment needs to follow those details as well.
| Illustrative day | AC solar surplus available | Later demand to cover | 5kWh battery | 10kWh battery | 15kWh battery |
|---|---|---|---|---|---|
| Modest evening demand | 7kWh | 4kWh | 4.00kWh | 4.00kWh | 4.00kWh |
| Larger evening and morning demand | 12kWh | 9kWh | 4.75kWh | 9.00kWh | 9.00kWh |
| High demand with abundant surplus | 18kWh | 13kWh | 4.75kWh | 9.50kWh | 13.00kWh |
| Cloudy day with high demand | 3kWh | 13kWh | 2.71kWh | 2.71kWh | 2.71kWh |
How the Table Is Calculated
Look at the cloudy-day row first. Just 3 × 0.9025 = 2.7075kWh, rounded to 2.71kWh, reaches the home. Every battery has enough space; there is simply not enough charging energy. On the day with abundant surplus and 13kWh of later demand, the 15kWh option supplies all 13kWh, while the 10kWh option reaches its 9.5kWh delivery limit.
The first row shows why buying a larger battery need not save anything extra that day. The second gives a useful improvement from 5 to 10kWh, but nothing further from 15kWh. The third makes the additional capacity useful. The fourth explains why winter grid charging may matter more than adding storage space. We want your size comparison to make those differences visible.
We would not turn one sunny day's result into a yearly claim by multiplying it by 365. For an annual estimate, we need weather and demand over time, the remaining charge and your actual tariff. You should be able to see how often each option fills, reaches its reserve and leaves worthwhile demand for the grid to supply.
A 15kWh Battery Is Not Necessarily More Powerful Than a 5kWh Battery
Capacity in kWh tells you how much energy you can store; power in kW tells you how quickly you can use it. Even a full battery cannot overcome the inverter's output limit. If the complete system can continuously supply 3kW and your home needs 6kW, it cannot provide that load alone. During normal grid-connected operation, the grid can supply the remaining 3kW.
Think about the moments when several things are running together: cooking, an electric shower, an immersion heater or EV charging. If avoiding those grid imports matters to you, we need suitable continuous power as well as capacity. A brief peak or surge rating is not the same as being able to sustain that output through a busy evening.
Some systems gain permitted power when modules are added; others remain limited by the same inverter. Charge level, temperature and module count may also affect output. We check the configuration actually being offered to you, rather than use the highest figure advertised somewhere else in a manufacturer's range.
| Constant household load | 5kWh | 10kWh | 15kWh |
|---|---|---|---|
| 0.5kW | 9.5 hours | 19 hours | 28.5 hours |
| 1kW | 4.75 hours | 9.5 hours | 14.25 hours |
| 2kW | About 2.38 hours | 4.75 hours | About 7.13 hours |
For the runtime examples, we divide delivered energy by a constant load and assume the system can sustain it. Separately measured standby use is excluded. Your real appliances switch on and off, and a short high demand can exceed the output limit even when average use is low. These figures illustrate stored energy; they do not establish whole-home power-cut backup.
Can Overnight Charging Make a Larger Battery Worthwhile?
Overnight charging can make a larger battery useful, particularly when solar generation is low. A suitable system buys grid electricity during cheaper hours and supplies it later when imports cost more. We then size around the demand between charging opportunities as well as the solar surplus, rather than assume the panels must refill the battery every day.
The price difference still has to cover storage losses and additional operating costs. Using our assumed 90.25% round-trip efficiency, electricity bought at an illustrative 10p/kWh costs 11.08p per delivered kWh . Replacing a 27p import leaves approximately 15.92p per delivered kWh before other costs and the purchase price. That helps explain the opportunity without treating the charging rate as the final cost.
Can the Battery Refill Inside the Cheap Window?
We also check whether the cheap window is long enough. Our 15kWh usable DC example needs about 15.79kWh at the AC charging input to refill completely. Over four hours, that means an average 3.95kW going into the charger. Your supply must accommodate the rest of the home, including any EV or heating demand running at the same time.
With a 3kW AC charging-input limit, four hours provides no more than 12kWh before losses. At our assumed efficiency, that adds at most 11.4kWh to usable DC storage from its minimum. A larger enclosure does not solve the charging limit. Energy left from earlier, more charging time or solar later in the day could change the picture, so we include those details rather than assume a full refill.
Charging power and discharge power need separate checks. A high output figure does not guarantee an equally high permitted grid-charging rate, and charging may slow or be curtailed. Where your tariff has more than one useful cheap window, a smaller battery may recharge between periods of demand instead of having to bridge the entire day.
Tariff Eligibility Comes Before a Savings Forecast
Before relying on a low tariff rate, we need to confirm that you can actually use it. EV tariffs may require a car charged at home, heating tariffs may require qualifying equipment, and solar-and-battery products have their own conditions. Meter communication, supported devices, import and export compatibility, every unit rate and the standing charge all belong in the comparison.
Your charging schedule should also consider tomorrow's solar. Filling the battery from the grid before a bright morning may leave no room for surplus generation. Sometimes exporting that solar is financially worthwhile; sometimes leaving storage space makes more sense. We compare the whole import and export bill with you, rather than treat either approach as always right. We explore the bill calculation further in our time-of-use battery guide .
Do an Electric Car or Heat Pump Mean You Need 15kWh?
Electric Cars: Separate Driving Energy from Household Storage
An electric car can add a lot to your annual electricity use, but that does not mean you need to put all its energy through a home battery. If you can charge directly during cheaper hours, you avoid the extra home-storage conversion losses and leave the battery available for household demand later.
The same applies when your car is at home during solar generation: it may be able to use surplus directly. We look at the demand remaining after those practical charging arrangements. We also check the controls, so the home battery does not unintentionally empty into the car when you intended to keep that energy for the house.
A larger battery may still help if you genuinely need vehicle charging outside affordable periods. We would compare its extra installed cost with changing the charging schedule. A future bidirectional car system is a separate compatibility and connection question; it should not be counted as an available home-energy source until the exact supported arrangement is confirmed.
Heat Pumps: Use Electricity Input, Not Heat Output
With a heat pump, we look at electrical demand rather than the heating-output label. Use varies with the weather, building, operating temperatures and controls. A "10kW heat pump" is not necessarily drawing 10kW of electricity continuously, so that label cannot simply be dropped into a battery runtime calculation.
Measured or properly modelled electrical use is more helpful, including hot water and any auxiliary heater during the periods you want to cover. Winter demand may make 10 and 15kWh worth comparing, but those are also the months with more limited solar charging. We need the grid-charging plan, heating schedule and battery output to work together.
Where it is safe and suitable for your heating system, moving hot-water production or some heating into cheaper periods may reduce the storage you need. We compare that without losing sight of comfort. A battery should fit the way your home is heated, not force you to work around an unsuitable size or schedule.
Is the Extra 5kWh Worth Paying for?
When we compare sizes with you, the question is not just whether the larger battery saves money. It is whether it saves enough more than the smaller option to justify its extra cost. We compare 5 with 10kWh, then 10 with 15kWh, using the same household data, solar system, tariff, reserve policy and study period.
Storing Solar Has an Export Opportunity Cost
Stored solar also has a cost to consider when you could have been paid to export it. Keeping that electricity means giving up the export income. So, for each extra unit the larger battery supplies to your home, we account for the solar energy needed to charge it and the payment you would otherwise have received.
Illustrative Value of Extra Solar Storage
For example, use a 27p import price, 12p export price and 90.25% round-trip efficiency. Supplying one extra kWh from storage takes about 1.108kWh of charging energy. The forgone export income is around 13.30p, leaving a gross benefit of 13.70p per additional delivered kWh . These are illustrative total payable rates, not an available supplier offer.
| Additional annual delivery to the home | Gross annual benefit at the example rates | Simple recovery of an illustrative £1,000 extra installed cost |
|---|---|---|
| 300kWh | £41.11 | About 24.3 years |
| 600kWh | £82.22 | About 12.2 years |
| 900kWh | £123.33 | About 8.1 years |
For this comparison, the extra £1,000 and the annual delivery figures are assumptions, not a quote or a prediction for another 5kWh module. Displayed values are rounded from unrounded calculations. Simple cost recovery excludes ageing, finance, maintenance, replacement, extra standby use and tariff changes. A recovery period longer than the expected service life is not evidence of a worthwhile investment.
If some extra charging comes from the grid, we use its charging cost instead of forgone solar export income. If rates vary through the day, we use the prices at the relevant times. It takes more care than multiplying capacity by one headline saving, but it avoids counting the same electricity as both exported and used at home.
What a Fair Annual Comparison Should Show
You should be able to compare useful battery delivery, charging losses, grid imports, paid exports and the resulting bill for each size. We also keep direct solar use and demand moved without storage visible. Any saving you could make simply by changing tariff belongs in the no-battery comparison, not entirely in the battery's claimed return.
A useful annual model carries the remaining charge from one interval to the next and applies power limits and reserves. We also want to see what happens with less solar or a narrower tariff gap. Assuming a full cycle every day for every battery is not enough to support a purchase, however tidy the resulting forecast looks.
Our Practical Test for Stepping Up a Size
Our advice is to choose the larger option when its extra capacity meets a real need often enough to justify the cost, or when you knowingly value the additional backup it provides. Ask us what the last 5kWh contributes. That question helps separate a worthwhile upgrade from simply buying a larger system.
How Does Backup Change the Capacity You Need?
Backup starts with a suitable installation, not the kWh rating. To supply agreed circuits safely during a grid failure, the system may need an appropriate gateway, changeover arrangement, protection and essential-loads circuit. Ordinary grid-connected solar and battery operation does not automatically keep your appliances running when the grid goes down.
Tell us what you want to keep on and for how long. A fridge, lights, internet equipment and heating controls are very different from electric heating, cooking and EV charging. We check continuous output, appliance starting demand and whether solar can recharge the battery during an outage. Those details help us discuss capacity for the backup you actually need.
In our 10kWh usable DC example, a reserve of 20% of usable capacity leaves 8kWh for normal cycling. At 95% discharge efficiency, that gives up to 7.6kWh for everyday bill savings. The 2kWh held back could supply approximately 1.9kWh if released for backup, before separately measured auxiliary use: around 3.8 hours at a constant 0.5kW essential load.
That is an illustration of the trade-off, not a recommended reserve for every household. A manufacturer's percentage may use a different charge scale, and the battery may contain more than its reserve when the outage begins. We explain what your actual setting means rather than promise a fixed number of backup hours from the percentage alone.
Keep Backup and Normal Savings Energy Separate
Energy kept for outages is not also available for normal daily savings. If that reassurance matters enough to justify a bigger battery, it is a valid priority to discuss separately. Your proposal should then identify the backup circuits, reserve settings and expected runtime, so you know exactly what the extra capacity is intended to achieve.
Can You Start Smaller and Add Capacity Later?
Some modular batteries can be expanded later, but we would want to explain what expandable means for the exact system. Maximum capacity, module generations, age or condition restrictions, inverter limits and approved combinations all matter. You cannot assume a new battery of any type can be connected to an existing one.
Starting smaller may make sense when your future demand is uncertain. It can also cost more overall if expansion needs another visit, extra wiring, a different inverter or network approval. We compare the price of the larger installation now with a clearly explained expansion route, rather than promise that adding capacity later will always be easy or cheaper.
Space, Temperature and Installation Design Matter
There is also the practical question of where everything will go. We compare the complete system's dimensions, weight, mounting and clearances; three modules need a different arrangement from one enclosure with similar capacity. The position must suit your home, the manufacturer instructions and the relevant installation and fire-protection requirements.
An unused loft or cupboard is not automatically a suitable battery space. Domestic siting requirements include restrictions on bedrooms, escape routes and lofts within the relevant safety specification's scope. We assess outdoor or indoor suitability, separation and detection for your actual property, rather than choose a location simply because the equipment fits.
A stated temperature range does not mean unrestricted performance at every temperature within it. Cold conditions can limit charging, while heat may reduce output on some systems. We look at whether the proposed position affects winter charging, usable energy or the battery's own electricity consumption. Location can influence how useful the capacity is throughout the year.
Network Connection Is About the Complete Electrical Configuration
The G98/G99 network-connection process concerns the equipment configuration and aggregate generating output per phase, not battery kWh alone. Existing solar and a battery inverter need considering together where applicable. An export limit does not automatically remove the connection requirements either, so choosing capacity is only one part of the design.
We explain the appropriate notification or application route, including any export limitation, for your proposed system. Your local network operator's requirements and available supply can affect the final arrangement. If you expand later, the equipment or permitted power may change and the connection may need reviewing again.
Compare Installed Cost, Warranty and Long-Term Performance
When comparing prices, make sure you are comparing complete installations. The battery, inverter or charger, controls, protection, mounting, electrical work, commissioning and requested backup equipment all count. Check network work, remedial electrical work, monitoring services and labour cover too. A cheaper-looking quote may simply leave more for you to pay afterwards.
Price per nominal kWh is only one measure. A low figure is less helpful if the extra capacity is not useful for your routine, output is inadequate or necessary work is missing. A higher price may include power capability or backup absent from another proposal. We want those differences clear enough for you to decide what is worth paying for.
Qualifying installed residential battery storage is covered by the temporary 0% VAT rate through 31 March 2027 , with 5% scheduled from 1 April 2027 . Eligible standalone installations are included as well as storage with solar. Supply-only purchases do not automatically qualify. We explain the treatment for your particular quotation and the applicable installation date and scope.
Read the Warranty Beyond Its Headline Years
We also look beyond the warranty's number of years. Retained capacity, permitted operating modes, cycle or energy-throughput limits, registration, connectivity, servicing and installation conditions may all matter. The term alone does not promise that your battery will keep its original capacity throughout the period.
For a planning illustration, suppose a battery that started with 10kWh usable DC capacity eventually retains 80%. It then has 8kWh on that basis. At the same assumed 95% discharge efficiency, with no extra reserve, it supplies 7.6kWh. This shows what reduced capacity would mean; it is not a forecast of how quickly any particular battery will age.
Ask us how ageing is reflected in the forecast and what happens if performance falls below the warranted level. Replacement equipment, fitting labour, access costs and temporary loss of service may have different cover. Knowing that before purchase is more useful than discovering the distinction when you need support.
What Should a Useful 5, 10 and 15kWh Quotation Show?
By this point, you should have a clearer idea of why we do not choose a battery from a bedroom count or a standard package alone. Your proposal should connect your electricity use to the equipment, operating plan and price. These are the details we want you to be able to compare and question.
Your Battery-Sizing Quotation Checklist
- Exact equipment: battery model, number of modules, inverter and control equipment.
- Capacity basis: nominal and usable energy, AC or DC measurement point, protective minimum and customer reserve.
- Power: continuous charge and discharge limits for the proposed configuration.
- Demand: the electricity use to be covered and the evidence behind it.
- Charging: solar surplus, grid windows and the practical time needed to refill.
- Annual comparison: useful delivered kWh, imports, exports and bill savings for each size.
- Marginal benefit: the extra annual value and installed cost of stepping up to the next size.
- Installation: location, electrical work and the applicable network connection route.
- Backup: included circuits and equipment, reserve policy and load assumptions, if requested.
- Ownership: warranty, monitoring fees, handover, support and confirmed expansion rules.
Already have panels? Our solar battery storage service can assess an addition alongside your existing equipment. Starting from scratch? We can look at solar and storage as one design, so the battery is chosen around your roof and routine rather than in isolation.
Choose a Battery Around Your Home’s Actual Energy Use
Bring us your annual electricity use, tariff, solar details and any half-hourly records you have. Tell us about the car, heating and backup priorities too. We will work through whether 5, 10 or 15kWh is worth considering for your home, with a clear explanation of what the extra capacity would actually do.